Lists allowable and recommended dry bulb and humidity ranges by ASHRAE class.

Datacenter & Hosting

Recommends RH and dew point setpoints from equipment class and climate inputs.

Datacenter & Hosting

Converts temperature and relative humidity into dew point and absolute moisture.

Datacenter & Hosting

Estimates enthalpy and wet bulb values from temperature and humidity readings.

Datacenter & Hosting

Computes SHR from sensible and total cooling loads to flag latent issues.

Datacenter & Hosting

Estimates free cooling hours and savings from climate temperature bins and load.

Datacenter & Hosting

Sizes rear door heat exchanger capacity per rack from rack kW and airflow inputs.

Datacenter & Hosting

Places in-row units along a row from rack kW profile and spacing rules.

Datacenter & Hosting

Checks whether surviving in-row units cover row heat after a unit failure.

Datacenter & Hosting

Rates a facility for direct liquid cooling from power, water and floor inputs.

Datacenter & Hosting

Estimates coolant flow rate and captured heat for a direct-to-chip GPU rack.

Datacenter & Hosting

Sizes immersion tank volume from device volume, fluid displacement and service space.

Datacenter & Hosting

Plans CDU count and loop allocation from rack heat loads and secondary flow.

Datacenter & Hosting

Evaluates supply air temperature choices against dew point and energy tradeoffs.

Datacenter & Hosting

Computes required CFM from heat load and target supply return temperature split.

Datacenter & Hosting

Estimates server fan power increase from inlet temperature rise inputs.

Datacenter & Hosting

Flags hotspot racks from pasted inlet temperature readings against a target.

Datacenter & Hosting

Converts thermal camera findings into prioritized airflow remediation tasks.

Datacenter & Hosting

Sizes portable cooling tonnage for a closet or hotspot from load and duty cycle.

Datacenter & Hosting

Plans condensate drain routing and trap details per cooling unit position.

Datacenter & Hosting

Recommends CRAC positions and spacing from room dimensions and airflow pattern.

Datacenter & Hosting

Flags recirculation paths from rack face, door and containment description input.

Datacenter & Hosting

Estimates minutes to temperature threshold after cooling loss from thermal mass inputs.

Datacenter & Hosting

Compares fixed versus tracking fan speed policies for energy and cooling risk.

Datacenter & Hosting