Plans metering points from utility service down to rack PDU with roll-up structure.

Datacenter & Hosting

Compares your kW per rack against industry benchmark ranges by facility type.

Datacenter & Hosting

Computes demand charge savings from battery or generator contribution during peaks.

Datacenter & Hosting

Recommends offline, line-interactive or double-conversion UPS from load criticality.

Datacenter & Hosting

Computes hydrogen dilution airflow from float current and battery count.

Datacenter & Hosting

Reads a battery runtime curve table and interpolates runtime at your load point.

Datacenter & Hosting

Compares two tariffs against a pasted load profile for annual cost difference.

Datacenter & Hosting

Ranks loads into shed tiers with kW per tier for capacity events.

Datacenter & Hosting

Checks emergency power off placement, signage and guard requirements.

Datacenter & Hosting

Compares commissioned kW against peak measured kW to output headroom per chain.

Datacenter & Hosting

Projects when to add UPS modules from load growth rate and frame capacity.

Datacenter & Hosting

Turns a facility power walk into a scored checklist of PDU, UPS and panel checks.

Datacenter & Hosting

Converts IT load kW into cooling tons and BTU per hour with redundancy margin.

Datacenter & Hosting

Sizes number and rating of CRAC units from total IT load and redundancy choice.

Datacenter & Hosting

Computes GPM flow from cooling tons and supply return delta T.

Datacenter & Hosting

Splits block IT load into chiller plant capacity with redundancy staging.

Datacenter & Hosting

Compares unit counts needed for N, N+1 and 2N cooling at your load.

Datacenter & Hosting

Scores hot aisle containment inspection points into pass, fix and not-applicable items.

Datacenter & Hosting

Scores cold aisle containment items from doors and roof panels to sensor placement.

Datacenter & Hosting

Compares hot and cold aisle containment on cost, retrofit effort and fire code factors.

Datacenter & Hosting

Assigns alternating rack faces into hot and cold rows from your row list.

Datacenter & Hosting

Estimates CFM lost to missing blanking panels, cutouts and unsealed floor openings.

Datacenter & Hosting

Estimates delivered CFM per rack from tile open area, count and floor pressure.

Datacenter & Hosting

Suggests perforated tile repositioning from a rack kW hotspot map input.

Datacenter & Hosting